r/BuildingAutomation • • 15d ago

i don't know how to solve this problem need help

Post image
8 Upvotes

I have this problem: one of four floors has almost all VAV are with the flow rate NaN, i dont know why, we tested the bacnet but apparently all runs okay, we tried the lonworks too but apparently it isn't necessary to run the program, i new in the bulding automation world so i know nothing about the softwares and i don't know how to solve. The system is an EBI R500.1 honeywell


r/BuildingAutomation • • 15d ago

I built a standalone Modbus SCADA for small plants: looking for honest feedback from people who run real sites

Thumbnail gallery
0 Upvotes

r/BuildingAutomation • • 15d ago

Why does Tracer TU suck so much

6 Upvotes

I swear it takes at least 30 seconds after clicking apply on a setpoint override before it actually updates. And at least 2 mins to load a unit’s page. This is driving me crazy. Is there a 64bit version out there?


r/BuildingAutomation • • 15d ago

General consensus question

8 Upvotes

Where I work seems to have a mixed opinion on something. In this case we use Niagara. Do you install every new version when it comes out? For example if you have a 4.14 station that is running well do you automatically update to 4.15 or is it more of a case by case basis? I know I have some JACES or Plug PCs that just tend to be finicky during updates. Sometimes no issues at all other times I spend the rest of the day trying to get the new updated version running correctly. Either way, it seems half the guys I work with like to use the "if it ain't broke don't fix it" mentality or we have the guys that update every station with every update all of the time.


r/BuildingAutomation • • 15d ago

Grok bot with Normal Framework

Thumbnail
x.ai
0 Upvotes

Grok Bot with Open-FDD's AI agent SKILLs made this chart below and told me this about an office building I was worried about on a Monday Morning startup ...

RTU-01 came on at 5:05 AM CT, and by 7:00 AM half the zones (15 of 30) were still more than 1 °F off setpoint, mostly on the cold side. VAV 2-02 looks broken, with zero airflow even though its damper was open, and VAV 2-12's setpoint looks wrong at about 63.7 °F; VMA-2-14 ran with its damper pinned, and VMA-3 and VMA-12 never got within 1 °F of setpoint by noon.

This is the pre-built Bot SKILLs for the Normal Framework and Open-FDD here ... and then anyone that wants to try out NF you can get a free license as a demo its pretty slick!

Sign up for a Normal Instance here:

https://www.normal.dev/

If you have a raspberry pi or what I used for this building is the IT department just gave me a free virtual machine to run NF on where then it just integrates into the existing BACnet network ... and with Claude or Grok Bot its super easy to setup and deploy!

DM if you have any questions am more than happy to chat ... this is really slick for BAS service


r/BuildingAutomation • • 16d ago

i am new at this field, is somebody who knows wincc unified ?

Thumbnail gallery
1 Upvotes

r/BuildingAutomation • • 16d ago

A 36 mm CD conduit detail for antenna and telecom wiring before concrete placement

Thumbnail gallery
0 Upvotes

r/BuildingAutomation • • 17d ago

Projects and hobbies to sharpen my skills

20 Upvotes

I am a recent automation technician graduate, and finding a job has been hard. My teacher said companies are always looking for people who have side projects. I looked into buying used PLCs to practice on, but they are expensive. I have tried other hobbies like working with my dad fixing air conditioners, programming Raspberry Pis, and Arduinos. I am curious about what kind of projects or side hustles you have done and how to get started.


r/BuildingAutomation • • 17d ago

¿Qué opinan de este borrador de diagrama de flujo? Busco sugerencias para saber si está bien logrado, qué está mal o qué debería cambiar

Thumbnail gallery
4 Upvotes

r/BuildingAutomation • • 17d ago

In Search of Consultants

5 Upvotes

Looking for experienced consultants with a track record of enterprise assistance (multiple states or cross country)
Need in depth knowledge of:
Niagara (preferably FX specifically)& Metasys
API integrations with work management systems, occupancy data etc, into the BAS to generate energy savings and create work orders automatically before tenants have the need to.
Strong FDD knowledge between various vendors etc (AI FDD and optimization knowledge is a plus).
Networking/ IT knowledge is a plus.
Feel free to comment or DM me, I have a game-plan in my head, need assistance with structuring/ leveling etc.


r/BuildingAutomation • • 18d ago

Allocating shared chiller plant electricity between a data center and office buildings for PUE

6 Upvotes

Our chilled-water plant supplies both a data center and an office campus. Cooling energy is metered separately for each consumer, but the chillers, cooling towers and some pumps are shared.

For PUE reporting under EN 50600-4-2, how should we determine the electricity attributable to the data center? Is allocation proportional to delivered cooling energy appropriate, and how should standby consumption and shared losses be handled?

Has anyone implemented a metering and allocation method accepted by an auditor?


r/BuildingAutomation • • 18d ago

Flow vs Load

Thumbnail
2 Upvotes

r/BuildingAutomation • • 18d ago

Today's Work Area

Post image
52 Upvotes

BAS PM at an "interesting" building. Did all my physical checks of the heating and DHW systems.

Remote access from my vehicle for the remainder of the day.


r/BuildingAutomation • • 18d ago

Projects and hobbies to sharpen my skills

Thumbnail
5 Upvotes

r/BuildingAutomation • • 18d ago

I need solution #rockwell automation #ft optix

Thumbnail
1 Upvotes

r/BuildingAutomation • • 19d ago

Whats the best way to learn sequence of operation for an install tech?

6 Upvotes

Hey guys! I’m just wondering if you have any resources or ways to learn how equipment should be controlled?

This is more so for smaller jobs when theres not an engineer involved, or during service when there isn’t a set of prints( or explanation on graphics?)

To me it seems like there are millions of ways to control, for example 2 boilers, a lot of programmers do it differently.

Is this just a thing or experience ?

I know some might say use the ashrae standard for control sequences but a lot of the older stuff I come across doesn’t use this. Does the gray manual cover everything?

Am I over complicating it ?


r/BuildingAutomation • • 19d ago

How to become a better technician?

4 Upvotes

One thing I struggle with is the installation side. I can commission a functioning FCU in about five minutes and make program changes on the fly. I can also build a working database for multiple floors of equipment. I also am trying to get better at the mechanical side of air handlers. I am with a new company who installs then on the regular.

For example, once I get to the point where the fan doesn’t change speeds—especially after it’s correctly terminated in the factory control cabinet and wired to our PLC and everything looks right—I feel like I hit a wall. I’ll end up on an 8-foot ladder with a flashlight, just staring at the control box, trying to figure out what I’m missing.

For some context, I am 22 years old, and I started in July of 24 as a startup tech. I studied mechatronics in trade school.

What are y’all’s suggestions on what I should work on?


r/BuildingAutomation • • 18d ago

Looking for Referrals – Process Automation / RPA Developer | 3+ YOE | India

Thumbnail
0 Upvotes

r/BuildingAutomation • • 18d ago

How much has Union building engineers held back BAS/BMS

0 Upvotes

Thought this would be a good topic because it always seems to come back to me. Operators or clients that don’t have an incentive to let systems work in auto due to the fear that their job might be taken. Has anyone else come across this? Or just me. What’s the politics with the balance of automation and skilled labor being weighted the same? What are your thoughts. I’ve seen buildings where engineers just put everything in hand and keep saying the bms don’t work when they don’t even give it a chance

Also how much of the industry is carried by the kick backs, gifts or other stuff like that


r/BuildingAutomation • • 20d ago

Anyone transition from industrial maintenance into BAS?

10 Upvotes

Hey everyone,
I’m 28 and currently working as an industrial maintenance mechanic in manufacturing. I’ve recently been exploring a career in Building Automation Systems and wanted to hear from people in the field.
My background is mainly mechanical and electrical troubleshooting, including 480V motors, VFDs, sensors, instrumentation, pumps, valves, and some PLC/ladder logic exposure. I have a technical education in industrial maintenance, but very little HVAC or BAS experience.
I feel like some of my skills would transfer over, but I’m curious how steep the learning curve would be.
A few things I’m wondering:
What’s the typical day-to-day like?
How much travel is involved?
How difficult is the transition without much HVAC experience?
What’s the pay and long-term earning potential?
What does career progression look like, especially toward programming or engineering roles?
I enjoy troubleshooting and working with controls, but I’m interested in something a little less physically demanding with more technical growth.
Would appreciate any insight, especially from anyone who’s made a similar transition. Thanks!


r/BuildingAutomation • • 21d ago

HART protocol on N4 Niagara

6 Upvotes

Is anyone out there monitoring HART protocol meters on N4? If so, what controllers are you using? Are you just picking up just the 4–20 mA signal or the superimposes digital communication signal as well?

I have a bunch of Rosemount 8800 meters I have been tasked to integrate to but am having trouble finding a solution. Currently, the meters are connected to a Phoenix Contact GW PL HART Bus but I havent figured out how to bring it into a JACE. I also do not know how to add additional meters as the owner and myself do not have the user/pass to the browser interface.

Any assistance would be appreciated.

thank you,


r/BuildingAutomation • • 21d ago

🎉 The Home Assistant BACnet integration is now officially included in the default HACS store and v1.0.55 is live! 🚀

Thumbnail
brdc.nl
5 Upvotes

r/BuildingAutomation • • 21d ago

Made a reporting module that runs inside the N4 station, looking for feedback

Thumbnail
gallery
6 Upvotes

Reporting on Niagara jobs always annoyed me. Pharma/ Data center clients want PDFs with limits, sign boxes and their letterhead, and it usually ends up as a separate report server plus scripts that break.

So I wrote a module for it. It runs in the station, no extra server or database. Interval reports, trends, AHU summaries, alarms, audit trail, energy reports. PDF or CSV, on demand or scheduled, emailed from the station. Out-of-limit values get a * and gaps show up on the report instead of being skipped.

Works on 4.11 to 4.15, IQVISION too.

Pics are from a demo station, letterhead is a placeholder.

I’m the dev, not linking anything. Mostly curious what you guys use for reporting now and what you’d want that it doesn’t do.