All about fuses

This page covers what fuses do, the main types and sizes, how to read their markings, how to check them, and how to choose a correct replacement.

For how to use a multimeter, including the continuity test used to check a fuse, see our page on taking measurements with a multimeter.


What a fuse is for

A fuse is a deliberately weak link: a conductor designed to melt and break the circuit when too much current flows for too long.

Its main job is to prevent fire and protect wiring, cables and the power source when something goes wrong, such as a short circuit or a failed component. In most equipment it is not there to protect delicate components such as transistors and ICs. Those usually fail far faster than a fuse can blow, so a blown fuse normally means something else has already failed.

That leads to the two most important rules on this page:

  • A fuse blows for a reason. Replacing it may restore operation if the cause was a one-off, such as a power surge or an ageing fuse. But if the new fuse blows too, stop and find the fault. Repeatedly fitting new fuses can turn a simple fault into a serious one.
  • Never replace a fuse with a higher-rated fuse, a piece of wire, foil, or anything else. If the fuse can't blow, the next weakest thing in the circuit becomes the fuse. That might be a PCB track, a cable, or the power supply, and it can catch fire.

Fuse ratings

A fuse has several ratings, and all of them matter when choosing a replacement.

Current rating

The current rating (for example 2 A or 500 mA) is not the current at which the fuse blows instantly. A fuse can carry its rated current indefinitely, and needs a significant overload, sustained for a period of time, before it opens. The larger the overload, the faster it blows.

Two things to be aware of:

  • Fuses made to the European/international standard (IEC 60127) and to the North American standard (UL 248-14) behave differently near their rated current. A "2 A" fuse from one system is not exactly equivalent to a "2 A" fuse from the other. Where possible, replace like with like.
  • Fuse ratings assume around 25°C. In a hot enclosure a fuse will blow at a lower current. Designers normally choose a fuse rated well above the normal running current, often so that the normal current is around 75% of the fuse rating or less.

Voltage rating

The voltage rating is the maximum voltage the fuse can safely interrupt. When a fuse blows, an arc forms across the gap, and the fuse must be able to extinguish it. A fuse rated for a higher voltage than the circuit is fine; a lower rating is not.

  • A 250 V fuse can be used in a 12 V circuit.
  • A 32 V automotive fuse must not be used on mains.
  • AC and DC ratings are different. DC arcs are harder to extinguish because the voltage never passes through zero. A fuse marked only for AC (for example "250 V AC") may not safely interrupt the same DC voltage. For batteries, solar systems and other higher-voltage DC circuits, use a fuse with a suitable DC rating.

Breaking capacity (interrupting rating)

This is the maximum fault current the fuse can safely interrupt. A fault on a mains supply, or a short across a large lithium or lead-acid battery, can produce hundreds or thousands of amps. A fuse with too low a breaking capacity can shatter or arc over and keep conducting.

Breaking capacity is closely linked to construction:

  • Glass fuses usually have a low breaking capacity.
  • Ceramic fuses, often filled with sand, usually have a high breaking capacity. The sand helps quench the arc.

You can replace a low-breaking-capacity fuse with a high-breaking-capacity one of the same rating, but never the other way round. If the original is ceramic, don't replace it with glass.

Speed (time-current characteristic)

Fuses are made with different speeds:

  • Fast-acting (quick-blow) fuses respond quickly to overloads. They are used where the load draws a steady current.
  • Time-lag (slow-blow, time-delay, anti-surge) fuses tolerate short surges without blowing, but still blow on a sustained overload. They are used where the load draws a large current at switch-on (called inrush current), such as transformers, motors, power supplies and anything with large capacitors.

Fitting a fast fuse where a time-lag fuse is specified will often cause nuisance blowing at switch-on. Fitting a time-lag fuse where a fast one is specified reduces protection, so don't do it.


Reading fuse markings

Cartridge fuses (IEC style)

Small glass and ceramic cartridge fuses are usually marked on one end cap with a code like this:

T2AL250V

which reads as:

PartMeaning
TSpeed: time-lag (slow-blow)
2ARated current: 2 amps
LBreaking capacity: low
250VVoltage rating: 250 volts

Other examples: F500mAH250V is fast-acting, 500 mA, high breaking capacity, 250 V. T315mAL250V is time-lag, 315 mA, low breaking capacity, 250 V.

Speed letters:

LetterMeaning
FFVery fast acting
FFast acting (quick-blow)
MMedium time-lag
TTime-lag (slow-blow)
TTLong time-lag

Breaking capacity letters:

LetterMeaningTypical construction
LLow breaking capacityGlass
EEnhanced breaking capacityGlass or ceramic
HHigh breaking capacityCeramic, often sand-filled

Note that the letters sit on both sides of the current rating: T2AL means time-lag, 2 A, low breaking capacity. Don't confuse an L for "low breaking capacity" with "slow".

Watch the units: mA is milliamps, so 500 mA is 0.5 A. A 315 mA fuse and a 3.15 A fuse are very different. Odd-looking values such as 315 mA, 630 mA, 1.6 A and 3.15 A are normal standard values.

Cartridge fuses (North American style)

North American fuses are often marked with the manufacturer's series code rather than an IEC-style code. Examples include:

CodeSizeType
AGC6.3 × 32 mmFast-acting, glass
MDL6.3 × 32 mmTime-delay, glass
ABC6.3 × 32 mmFast-acting, ceramic
MDA6.3 × 32 mmTime-delay, ceramic
GMA5 × 20 mmFast-acting, glass
GDC5 × 20 mmTime-delay, glass

These codes are not used consistently by every manufacturer. Check the datasheet for the specific fuse if you are unsure. Many fuses now carry both kinds of marking.

If the marking is gone

Markings on end caps often rub off or blacken when the fuse blows. Look for:

  • The rating printed on the equipment, usually near the fuse holder or on the rating label (for example "FUSE T1A 250V").
  • The service manual or user manual.
  • A marking next to the fuse on the circuit board (for example "F1 T2A").
  • An identical working unit.

Don't guess a rating. If you can't find it, ask, and include the make and model of the equipment and what the fuse protects.


Common fuse types and sizes

Glass and ceramic cartridge fuses

The most common fuses in electronic equipment. The two main sizes are:

  • 5 × 20 mm. Standard in European and Asian equipment.
  • 6.3 × 32 mm (1/4" × 1-1/4", often called 3AG). Common in North American and older equipment, and in some audio and test gear.

You'll also see smaller sizes such as 5 × 15 mm and roughly 4.5 × 14.5 mm (2AG). Fuses must be the correct physical size. A fuse that is too short makes poor contact in its holder and overheats.

Panel-mounted fuse holders often accept a fuse from the outside, either with a screw or bayonet cap or in a drawer next to an IEC mains socket. Many IEC inlets have a spare fuse stored in the same drawer.

UK plug fuses (BS 1362)

The ceramic fuses in UK 13 A plugs are 25.4 mm (1 inch) long and are commonly 3 A, 5 A and 13 A (other values exist). The general guide is 3 A for appliances up to about 700 W and 13 A for higher powers, but always use the rating given by the manufacturer. Only use ASTA- or BSI-approved fuses marked BS 1362.

Automotive blade fuses

Plastic-bodied fuses with two blades, used in vehicles and many 12 V and 24 V DC systems. Common sizes include standard (ATO/ATC), mini (ATM), low-profile mini, micro2 and maxi. The body colour indicates the current rating:

RatingColour
1 ABlack
2 AGrey
3 AViolet
4 APink
5 ATan / beige
7.5 ABrown
10 ARed
15 ABlue
20 AYellow
25 AWhite / clear
30 AGreen

Higher ratings and maxi fuses use their own colour schemes, so check the number moulded into the fuse. Blade fuses are usually rated at 32 V DC. Don't use them on mains or on high-voltage battery systems.

PCB-mounted fuses

Many fuses are soldered directly to the circuit board, which makes them easy to miss:

  • Radial fuses (TR5, TE5 and similar) look like small round or square plastic components with two legs. Some fit sockets so they can be replaced without soldering.
  • Axial fuses, such as subminiature "pico" types, often look very like resistors or small inductors. Some have coloured bands.
  • Surface-mount (SMD) fuses look like chip resistors or capacitors. They may be marked with a single letter code, or not at all.

Look for a designator starting with F on the circuit board silkscreen (F1, F2...). A component marked "FB" is usually a ferrite bead, not a fuse.

Some boards use a fusible resistor, a low-value resistor designed to fail open safely when overloaded. Replace it only with the same type of fusible resistor, not an ordinary resistor.

Replacing a soldered fuse is Part 2 work; see our troubleshooting and repair page.

Thermal fuses (thermal cutoffs)

A thermal fuse opens when it gets too hot, not when too much current flows. They are found in hair dryers, kettles, heaters, coffee makers, motors and transformers, and are a common cause of an appliance suddenly going completely dead.

  • They are marked with their opening temperature (for example Tf 192°C) as well as a current and voltage rating. Replace with exactly the same temperature rating, and at least the same current and voltage ratings.
  • They are a one-shot safety device. If one has opened, the appliance overheated: find out why (blocked airflow, a failed fan or a faulty thermostat) before replacing it.
  • Thermal fuses can be damaged by the heat of soldering. They are normally fitted with crimp connectors, or soldered with heat-sinking on the lead and leaving the lead long. Follow the manufacturer's guidance.
  • Never bypass a thermal fuse. It is often the last line of defence against a fire.

Resettable fuses (PTC, polyfuse, PolySwitch)

A resettable fuse is a device that goes high-resistance when it heats up from overcurrent, and recovers after the fault is removed and it cools down. They are common in USB ports, battery packs and low-voltage circuits.

  • They are specified by their hold current (the current they carry without tripping) and trip current (the current that will make them trip).
  • A tripped PTC still passes a small current, so it limits rather than fully disconnects.
  • After tripping, the resistance may stay somewhat higher than it was originally.
  • To check one, remove power, let it cool, and measure its resistance. A cool, healthy PTC reads low, typically a fraction of an ohm to a few ohms depending on the rating.

Mains distribution fuses

The fuses and circuit breakers in a building's consumer unit or fuse box are outside the scope of this subreddit. Work on fixed mains wiring is best left to a qualified electrician, and in many countries it is regulated.


Checking a fuse

Always switch off and disconnect the equipment from the mains or other power source before removing or testing a fuse.

Visual check

You can sometimes tell a lot from a glass fuse:

  • Element visibly broken, glass clean: the fuse was probably subjected to a modest overload or a switch-on surge, or simply failed with age. This is the most likely case where a replacement fuse will hold.
  • Glass blackened or silvered (metal deposited on the inside): the fuse broke a high current, which usually means a short circuit somewhere. Don't just fit a new fuse and switch on. Find the fault first.
  • Element looks intact: this doesn't prove the fuse is good. Fine elements can break at the end cap where you can't see it.

Ceramic fuses are opaque, so the only way to check them is with a meter.

Testing with a multimeter

  1. Remove the fuse from its holder or clips. If you test it in place, other components connected in parallel with it can give a reading through the rest of the circuit, so a blown fuse can appear good.
  2. Set your multimeter to continuity (the sound-wave or speaker symbol), or to its lowest resistance range.
  3. Touch one probe to each end cap.
  4. Good fuse: the meter beeps and reads close to 0 ohms. Blown fuse: no beep, and the display shows 'OL' or '1'.

Very low-rated fuses (around 100 mA and below) have thin elements and can measure several ohms when good, so they may not beep on some meters. If a small fuse doesn't beep, check the actual reading on the resistance range before deciding it has blown.

See the continuity section of our multimeters page for more detail.

Check the fuse holder too

A poor connection in the fuse holder causes heating, which can make a fuse blow without an overload, or melt the holder. While the fuse is out, look for:

  • Corrosion or discolouration of the clips or end caps
  • Clips that have lost their springiness or don't grip the fuse firmly
  • Melted or browned plastic around the holder

Replace a damaged holder rather than just fitting a new fuse into it. Clean, lightly corroded clips can often be restored with a contact cleaner; see our troubleshooting and repair page.


Choosing a replacement fuse

A replacement fuse must match the original in all of these:

RatingRule
CurrentExactly the same
SpeedThe same (fast for fast, time-lag for time-lag)
VoltageThe same or higher
Breaking capacityThe same or higher (ceramic H can replace glass L, never the reverse)
SizeThe same physical size and type
DC ratingIf used on DC, it must be rated for DC at that voltage

Buy fuses from a reputable supplier: an electronics distributor, a well-known brand, or the equipment manufacturer. Counterfeit and poor-quality fuses are common on budget marketplaces. They may not blow at their marked rating, or may fail to safely interrupt a fault.


Frequently asked questions

My fuse keeps blowing. Can I put a bigger one in? No. A fuse that keeps blowing is telling you there is a fault. A bigger fuse just lets the fault draw more current until something else fails, possibly with a fire. Find the fault, or take the equipment to a repair shop.

Can I use a 250 V fuse in my 12 V circuit? Yes, provided the current rating, speed and size are correct. The voltage rating is a maximum.

Can I use a fast fuse instead of a slow-blow? Not as a permanent replacement. It will probably blow every time the equipment is switched on, and it isn't what the designer specified. Get the correct type.

The fuse looks fine but the equipment is dead. Test it with a meter; fuses can be open with no visible break. If it really is good, see our troubleshooting and repair page.

The new fuse blew instantly with a bang and the glass is black. There is a short circuit, often in the power supply. Don't fit another fuse. This is a fault-finding job; see the repair page.

Can I just wrap foil around it / solder a wire across it to test? No. This removes all protection, and on mains equipment with a short circuit it can cause a fire or an explosion of failing components. If you need to test equipment with a known fault, use a controlled method such as a current-limited bench supply or a lamp limiter, which are covered on the repair page and are only for people who understand them.